Issue
Design data cannot be converted and an error message appears.
Cause
Design data cannot be converted due to the following reasons
- System error (P001)
This error message is displayed when duplicate registration of TP3 and GC3 localization files are registered, when a special character "=" is included in the file name, or when xml (linear data, etc.) with no 3D design data is registered.
- Data Conversion Error.
This message is displayed when duplicate registration of TP3 and TP3 is made, or when the volume of design data is too heavy.
How to deal
- Do not register more than one GC3 or more than one TP3 in one project.
- Do not use the special character "=" in the data name.
- Register xml containing 3D design data.
- Prepare the design data with a lighter capacity or TIN as much as possible.
If the above actions do not resolve the problem, or if any other error message is displayed, please contact the support center.