  • Porras Khimberly created an article,

    Error message "Out of 3D design data range" is displayed.

    Issue ”Out of 3D design data range" is displayed.   Answer The following review may improve the problem. Please check. Simplified Table (Main Factors) 項目 Confirmation details 1. Check if th...

  • Porras Khimberly created an article,

    Error message "Projection Error" is displayed.

    Issue Error message "Projection Error" is displayed in SC Pilot APP.   Cause Mistake in the projection settings (region, projection method, etc.) - Check that there are no mistakes in the projec...

  • Porras Khimberly created an article,

    Error message "Localization error" is displayed.

    Issue Error message "Localization Error" is displayed in SC Pilot APP. Cause Insufficient reference points for localization. -  Check the reference points for localization. At least four localiz...

  • Porras Khimberly created an article,

    Error message "Project file is not selected" is displayed.

    Issue Error message "Project file is not selected" is displayed on the tablet app.   Cause Project file not yet downloaded to the SC pilot app.   How to deal Download the project file/design file t...